BETEC CAD.


Go to content

Main menu:


Volume Control Dampers

Products

Volume Control Dampers

Volume control dampers are square and rectangular type with both parallel blade operation and opposed blade operation, Low leakage blade construction, is to suit for high performance applications where dampers are subjected to face quiet, efficient, rattle free operation.

VCD - GB-10, Galvanized Steel Construction.
3V Single; Low Leakage Rating to Class-2 ; Drive : Manual Quadrant: VCD-GB-10 / 20 A/B

VCD GB 10 Series is a galvanized steel high performance low leakage volume control damper, to ensure lowest resistance to airflow in HVAC systems with velocities to 2000 fpm (10.2 m/sec.) and 4” w.g. (1000Pa) may be installed vertically or horizontally (with blades running horizontally) and is rated for airflow and leakage class 2 in either direction. The standard construction is suitable for a leakage of <3% when fully closed position. The square and rectangular type VCDs are designed for handling maximum air capacities at minimum pressure drop.

Send Sales Enquiry


Volume Control Dampers

VCD - GB-20, Galvanized Steel Construction.
Aerofoil Blades; Low Leakage Rating to Class-2 ; Drive : Manual Quadrant: VCD-GB-10 / 20 A/B

VCD GB 20 Series is a galvanized steel high performance low leakage volume control damper, to ensure lowest resistance to airflow in HVAC systems with velocities to 2000 fpm (10.2 m/sec.) and 4” w.g. (1000Pa) may be installed vertically or horizontally (with blades running horizontally) and is rated for airflow and leakage class 2 in either direction. The standard construction is suitable for a leakage of <1% when fully closed position. The square and rectangular type VCDs are designed for handling maximum air capacities at minimum pressure drop.

Send Sales Enquiry


Round Volume Control Dampers

RVCD - GB-30, Galvanized Steel Construction.
Single Butter fly Blade; Low Leakage Rating to Class-2 ; Drive : Manual Quadrant: RVCD-GB-30

RVCD GB 30 Series is a galvanized steel high performance low leakage volume control damper, to ensure lowest resistance to airflow in HVAC systems with velocities to 2000 fpm (10.2 m/sec.) and 4” w.g. (1000Pa) may be installed vertically or horizontally and is rated for airflow and leakage class 2 in either direction. The standard construction is suitable for a leakage of <1% when fully closed position. RVCDs are designed for handling maximum air capacities at minimum pressure drop.

Send Sales Enquiry


Home | Products | Catalogue | Certifications | Projects | Organization | Sales | Services | Site Map


Back to content | Back to main menu